Labelmate C-200-US COUNTER FAQs

View Labelmate C-200-US COUNTER

The Labelmate C-200-US COUNTER, SKU 80-238-0012, is a non-motorised ultrasonic label counter for in-line label counting. It is positioned between a label printer and a separate rewinder to count label rolls up to 254 mm wide as they are rewound.

Q: What is the Labelmate C-200-US COUNTER used for?

A: The Labelmate C-200-US COUNTER counts labels passing through its sensor as the label web is drawn onto a separate rewinder. It is intended for in-line workflows, where it sits after a label printer and before the rewinder.

It is a counter rather than a printer, label dispenser or motorised rewinder. The counter provides a practical way to tally a printed roll during rewinding rather than manually counting labels.

Q: Does the C-200-US COUNTER include a rewinder?

A: No. The C-200-US COUNTER is non-motorised and requires a separate rewinder for its intended in-line counting workflow.

Plan the setup as separate equipment: a label printer or label supply, the C-200-US COUNTER, and a suitable rewinder. Position the counter between the printer and rewinder so the rewinder pulls the label web through the sensor.

Q: What label-web width can the C-200-US COUNTER handle?

A: The C-200-US COUNTER accepts label webs up to 254 mm, or 10 inches, wide.

For narrower material, set the guide rings to match the web width. Tighten the guide screws finger-tight only, then confirm the web remains aligned as it passes through the sensor slot.

Q: Can the C-200-US COUNTER count transparent labels?

A: Yes. The C-200-US COUNTER is the ultrasonic version of the 10-inch counter and is specified for transparent as well as opaque labels with gaps between them.

Its ultrasonic detection distinguishes backing material on its own from backing material carrying a label. This makes it suitable for clear label constructions where an ordinary optical approach may not be appropriate.

Q: Do labels need gaps for the C-200-US COUNTER?

A: Yes. The C-200-US COUNTER is specified for labels with gaps between labels. The ultrasonic sensor identifies each label from the change between liner-only and liner-plus-label sections of the web.

Check the construction of the labels before selecting or setting up the counter, particularly for transparent, dark or unusually shaped labels. Accurate detection depends on the sensor being able to distinguish each label position from the backing material.

Q: Can the counter stop a rewinder at a preset quantity?

A: Yes, when used with a CAT-3 label rewinder and the external halt connection, the preset counter can send a halt command when the selected quantity is reached.

To use this workflow:

  1. Connect the control cable between the counter display module output and the CAT-3 rewinder External Halt Control connection.
  2. Set the required quantity on the six-digit preset counter.
  3. Pull a short label strip through the sensor gap and confirm that the displayed count increases.
  4. When the preset count is reached, the counter sends the halt command to stop the CAT-3 rewinder.

Press RESET to clear the count and restart the CAT-3 rewinder. This stopping function is documented specifically for the CAT-3 external halt workflow.

Q: How do I thread labels through the C-200-US COUNTER?

A: Place the counter perpendicular to the label web. Follow the paper-path marking on the unit: route the web under the rotating metal paper guide, over the fixed nylon paper guide, then through the black sensor slot between the round guides.

Adjust the guide rings to the web width and tighten the screws finger-tight. Attach the web to the rewinder core after it has been routed through the counter. A correctly loaded web travels cleanly through the sensor air gap while the rewinder draws it forward.

Q: How do I calibrate the ultrasonic sensor after changing label material?

A: Use the self-learning ultrasonic calibration routine after changing labels or label material.

  1. Tension the label web between the supply roll and the rewinder.
  2. Select the ultrasonic sensor using the switch on the rear panel of the counter unit.
  3. Remove several labels so that liner only is in the ultrasonic sensor gap.
  4. Press + and – together for one second. The red LED flashes.
  5. Slowly move the web back and forth four to five times so the sensor can learn the label and liner.
  6. Stop with liner in the sensing area and press – once. The LEDs switch off.
  7. Run the web slowly. The yellow LED should flash for every detected label.

The yellow LED flashing once per label is the check that the sensor is detecting labels correctly.

Q: What should I check if the C-200-US COUNTER gives irregular counts?

A: Start with the web path and sensor setup, then clean the sensor if necessary.

  • Confirm the web passes under the rotating metal guide, over the fixed nylon guide and through the sensor slot.
  • Check that the guide rings suit the web width and are only finger-tight.
  • Recalibrate the ultrasonic sensor after a label or material change.
  • If counts remain irregular, clean the optical sensor with isopropyl alcohol.
  • Run the web slowly and check that the yellow LED flashes for each label detected.

If the count is still irregular after these checks, contact us for assistance.

Q: Can I use the C-200-US COUNTER for off-line roll checks?

A: Yes. The counter can be used as part of an off-line inspection and counting station when paired with an unwinder and a CAT-3 rewinder.

In that arrangement, a completed roll is unwound, passed through the counter and rewound. This supports roll-count verification or inspection work without requiring the labels to be counted directly as they print.

Q: What maintenance does the C-200-US COUNTER need?

A: The C-100 and C-200 counter platform is described as requiring no routine maintenance. Keep the label path and sensor area clean, and clean the optical sensor with isopropyl alcohol if counting becomes erratic.

There are no user-serviceable internal parts. Do not open the unit for internal repairs; contact us if an operational problem remains after checking web routing, guide alignment, calibration and sensor cleanliness.

Q: What safety checks matter when setting up the counter and rewinder?

A: Use the C-200-US COUNTER indoors in a dry location and on a level surface. Disconnect power before making adjustments or other manipulations, keep cables out of walkways, and keep the work area clear of obstacles.

The counter and rewinder have moving parts. Operators should be trained, understand the shutdown process, and keep hands, loose clothing, jewellery and unsecured hair away from the moving label web and rewinder. Do not place foreign objects in the operating area.

Contact us for help selecting a suitable rewinder or planning an in-line label counting setup.